Compact, rugged housing.
-
Stand-alone use or in combination with the OD Mini evaluation unit.
-
Display and LEDs on device for visualization of current status.
-
Different interfaces available.
-
Simple teach-in using display or external teaching input.
-
CMOS receiver unit for precise, fast measurement in the µm range.
-
Various measuring ranges: Measuring from 10 mm to 250 mm possible.
Technical overview:
Measuring range:
10 mm ... 250 mm
Linearity:
± 10 µm ... ± 100 µm
Repeatability:
20 µm
200 µm
1 µm
6 µm
Response time:
≥ 2 ms
Output time:
≥ 0.5 ms
Measuring frequency:
≤ 2 kHz
Digital output:
1 ... 3 x PNP/NPN, selectable
Light source:
Laser, red
Type of light:
Visible red light
Serial:
RS-485
PROFIBUS DP:
optional, over external evaluation unit
Analog output:
Number: 1
Type: Current output / voltage output
Ambient temperature, operation:
–10 °C ... +50 °C
Can't see what you're looking for? Contact us! We can provide further stock as to what's on our shop.