- Measurement range from 0.15 m to 300 m.
- Very fast measurement cycles.
- Highest accuracy, repeatability and system availability.
- Illuminated LC display with diagnostic information.
- Visible red light and bracket with springs for alignment.
- Variety of interfaces: SSI, RS-422, PROFIBUS, HIPERFACE, DeviceNet.
Technical overview:
Measuring range:
0.15 m ... 300 m, on reflective tape "Diamond Grade"
Repeatability:
0.5 mm
1 mm
2 mm
Output time:
0.2 ms ... 2 ms
Accuracy:
± 2 mm
± 3 mm
± 5 mm
Target:
Reflector
SSI:
Yes
PROFIBUS DP:
Yes
Serial:
RS-422
HIPERFACE®:
Yes
DeviceNet:
Yes
Ambient temperature, operation:
–40 °C ... +75 °C, operation with cooling case, operation with heating
Light source:
Laser, red
Type of light:
Visible red light
Laser class:
2 (IEC 60825-1:2014)